PV series Solar Pumping Inverter
- 33 -
3AI1+AI2
4AI1-AI2
5Max{AI1AI2}
6Min{AI1AI2}
7: DI7/HI pulse input
8AI3
F13.03
PID setting feedback
range
060000
1000
F13.04
PID action direction
0: Forward action
0
×
1: Reverse action
F13.05
Filtering time of PID
setting
0.00010.000s
0.000s
F13.06
Filtering time of PID
feedback
0.00010.000s
0.000s
F13.07
Filtering time of PID
output
0.00010.000s
0.000s
F13.08
Proportional gain Kp1
0.0100.0
1.0
F13.09
Integration time Ti1
0.0110.00s
0.10s
F13.10
Differential time Td1
0.00010.000s
0.000s
F13.17
PID offset limit
0.0100.0%
1.0%
×
F13.18
PID integral property
Unit's digit (Whether to stop
integral operation when the
output reaches the limit)
0: Continue integral operation
1: Stop integral operation
00
×
Ten's digit (Integral separated)
0: Invalid
1: Valid
F13.19
PID differential limit
0.0100.0%
0.5%
×
F13.20
PID initial value
0.0100.0%
0.0%
×
F13.21
Holding time of PID
initial value
0.06000.0s
0.0s
×
F13.22
PID output frequency
upper limit
PID output frequency lower
limit100.0%100.0%
corresponds to maximum
frequency
100.0%
×
F13.23
PID output frequency
lower limit
100.0%PID output frequency
lower limit
0.0%
×
F13.24
Detection value of
PID feedback loss
0.1100.0%
0.0%: Not judging feedback loss
0.0%
×
F13.25
Detection time of
PID feedback loss
0.030.0s
1.0s
×
F13.26
PID operation at stop
0: No PID operation at stop
0
×
1: PID operation at stop
Group F16 Keys and Display of Keypad Parameters
F16.01
Function of STOP/RST
key
0: STOP/RST key valid only
when under keypad control
1
×
1: STOP/RST key valid under
any run command source
F16.02
Keys locked option
0: Not locked
0
×
1: Full locked
2: Keys locked other than RUN,
STOP/RST
3: Keys locked other than
STOP/RST

Table of Contents