PV series Solar Pumping Inverter
- 46 -
small
larger power
Err04
Acceleration
Overvoltage
1Input voltage is high
2There is an external force
during acceleration dragging
the motor to work
3Acceleration time is too
short
4No installation of braking
resistor
1The voltage adjusted to a
normal range
2Cancel the external
power or install braking
resistor
3Prolong the acceleration
time
4Install braking resistor
Err05
Deceleration
Overvoltage
1Input voltage is high
2There is an external force
during deceleration dragging
the motor to work
3Deceleration time is too
short
4No installation of braking
resistor
1The voltage adjusted to a
normal range
2Cancel the external
power or install braking
resistor
3Prolong the deceleration
time
4Install braking resistor
Err06
Constant-speed
Overvoltage
1Input voltage is too high
2There is an external force
during running dragging the
motor to work
1The voltage adjusted to a
normal range
2Cancel the external
power or install braking
resistor
Err07
Bus Under
voltage
protection
1Momentary power failure
2The inverter input voltage
3Bus voltage abnormal
4Rectifier bridge and buffer
resistance are abnormal
5Drive board abnormal
6Control panel abnormal
1Reset Failure
2Adjust voltage to normal
range
3Ask for technical support
4Ask for technical support
5Ask for technical support
6Ask for technical support
Err08
Short circuit
protection
1 1Inverter output circuit
shorted
2 2Acceleration/ Deceleration
time is too short
3Wirings between motor and
inverter is too long
4Module Overheating
5Internal wirings of inverter
loosened
6Main Board Abnormal
1 1Peripheral
troubleshooting
2Prolong the
acceleration/deceleration
time
3Install the reactor or
output-filter
4Check and confirm the
air-channel unblocked, fans
operation normal