PV series Solar Pumping Inverter
- 22 -
Chapter Three Function Parameters
3.1 The Basic Function Parameters
Table 3-1 Basic Function Parameters
Function
Code
Name
Descriptions
Default
Value
Attribu
te
F00 Group: System Parameters
F00.00
User Password
0~65535
0
×
F00.04
Default Value Control
0:Null
0
×
1:Factory Reset(Excluding
motor parameters)
2: Clear the record information of
fault
3:Backup user’s current
parameters
4:User’s backup parameters
were restored
F00.13
Carrier frequency
0.700~16.000kHz
Model
defined
△
F00.18
Fan control
0: Run at power-on
1
×
1: Fan working during running
F00.20
Inverter rated power
0.2~710.0kW
Model
defined
⊙
F00.21
Inverter rated voltage
60~660V
Model
defined
⊙
F00.22
Inverter rated current
0.1~1500.0A
Model
defined
⊙
F00.23
Software version
0.00~655.35
Model
defined
⊙
F00.24
Dealer password
0~65535
0
×
F00.25
Setting operation time
0~65535h(0: Invaild)
0h
×
F01 Group: Frequency Given
F01.01
Master Frequency
Command Source
0:Master digital setting (F01.02)
1
×
1: keypad potentiometer
2: Analog input AI1
3: Communication
4: Multi-reference
5: PLC
6: Process PID output
7: X7/HI pulse input
8:AI2
9:AI3
F01.02
Digital Setting of Master
Frequency
0.00~Fmax
0.00Hz
△
F01.08
Maximum Frequency
20.00~600.00Hz
50.00Hz
×