EasyManua.ls Logo

Fronius Primo Series - Relevant Standards and Directives

Fronius Primo Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
EN-US
Relevant stan-
dards and direc-
tives
* Only for AFCI and insulation monitoring functions
Output frequency range
Setups: 50 Hz, 60 Hz
Setup: HI1
48.0 - 50.5 Hz / 59.3 - 60.5 Hz
- / 57.0 - 63.0 Hz
Grid frequency setting range 45.0 - 55.0 Hz / 50.0 - 65.0 Hz
Frequency trip limit accuracy 0.05 Hz
Frequency clearing time setting range 0.016 - 600 s
Harmonic distortion < 2.5 %
Power factor (cos phi) 0 - 1 ind./cap..
1)
General Data
Maximum efficiency 97.9 %
CEC efficiency at 208 V
at 220 V
at 240 V
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
Self-consumption at night at 208 V
at 220 V
at 240 V
0.4 W
0.6 W
0.6 W
Self-consumption during operation 10 W
Cooling Forced-air ventilation
Protection class NEMA4X
Dimensions h x w x d 28.5 x 20.1 x 8.9 inch
(725 x 510 x 225 mm)
Weight 82.5 lbs. (37.4 kg)
Shipping dimensions w x h x d 31.1 x 22.6 x 13.4 inch
(790 x 575 x 340 mm)
Shipping weight 90.2 lbs. (40.9 kg)
Permissible ambient temperature
(at 95% rel. humidity)
-40 °F - +140 °F (-40 °C - +60°C)
Permissible storage temperature
(with 95% rel. humidity)
-40 °F - +158 °F (-40 °C - +70°C)
Protection Devices
Insulation monitoring Integrated
Stand-alone operation protection Integrated
Reverse polarity protection Integrated
Arc detection/interruption Integrated
Overtemperature Operating point shift / active cooling
1) ind. = induktiv cap. = kapazitiv
Fronius Primo 11.4-1 208-240 12.5-1 208-240 15.0-1 208-240
- UL 1741
- IEEE 1547
- IEEE 1547.1
- UL 1998 *
- CSA TIL M07 Issue 1
- ANSI/IEEE C62.41
- UL 1699B Issue 2
- FCC Part 15 A & B
- NEC Article 690
- C22.2 no 107.1-01

Table of Contents