EasyManuals Logo

Fronius Primo Series User Manual

Fronius Primo Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
3
EN-US
Contents
Safety rules ................................................................................................................................................ 5
General ................................................................................................................................................. 5
Environmental Conditions ..................................................................................................................... 5
Qualified Service Engineers.................................................................................................................. 6
Data Regarding Noise Emission Values ............................................................................................... 6
EMC Measures ..................................................................................................................................... 6
Safety symbols...................................................................................................................................... 6
Disposal ................................................................................................................................................ 6
Backup .................................................................................................................................................. 7
Copyright............................................................................................................................................... 7
General ...................................................................................................................................................... 8
Device concept ..................................................................................................................................... 8
Intended Use......................................................................................................................................... 8
Information on "Field Adjustable Trip Points" and "Advanced Grid Features" ..................................... 9
FCC / RSS Compliance ........................................................................................................................ 9
Insulation Monitoring............................................................................................................................. 9
Arc Detector / Interrupter ...................................................................................................................... 10
Warning Notices Affixed to the Device.................................................................................................. 10
String Fuses.......................................................................................................................................... 11
Criteria for the Proper Selection of String Fuses .................................................................................. 11
RGM – Optional Revenue Grade Meter..................................................................................................... 13
General ................................................................................................................................................. 13
RGM Connection Options ..................................................................................................................... 13
Data Communication and Solar Net .......................................................................................................... 14
Fronius Solar Net and Data Interface ................................................................................................... 14
Installing Option Cards in Inverters....................................................................................................... 14
System monitoring ..................................................................................................................................... 15
General ................................................................................................................................................. 15
Starting for the First Time via the Fronius Solar.web App .................................................................... 15
More Detailed Information on Fronius Datamanager 2.0...................................................................... 17
Keys and symbols...................................................................................................................................... 18
Keys and Symbols ................................................................................................................................ 18
Display .................................................................................................................................................. 19
Menu level.................................................................................................................................................. 20
Activating Display Illumination .............................................................................................................. 20
Automatic Deactivation of Display Illumination / Switching to the "NOW" Display Mode...................... 20
Accessing the Menu Level .................................................................................................................... 20
Menu items NOW, LOG, and GRAPH ....................................................................................................... 21
NOW LOG GRAPH............................................................................................................................... 21
Values Displayed in the Menu Items NOW and LOG ........................................................................... 21
The SETUP menu item .............................................................................................................................. 23
Presetting.............................................................................................................................................. 23
SETUP .................................................................................................................................................. 23
Navigation in the SETUP Menu Item .................................................................................................... 23
General Setup Menu Item Settings....................................................................................................... 24
Application Example: Setting the Feed-In Tariff.................................................................................... 25
The Setup menu item................................................................................................................................. 26
Standby................................................................................................................................................. 26
WiFi Access Point ................................................................................................................................. 26
DATCOM .............................................................................................................................................. 27
USB....................................................................................................................................................... 27
Relay..................................................................................................................................................... 29
Time/Date ............................................................................................................................................ 29
Display Settings .................................................................................................................................... 30
Energy Yield.......................................................................................................................................... 31
Fan........................................................................................................................................................ 32
Arc Detection ........................................................................................................................................ 32
The INFO menu item ................................................................................................................................. 33
INFO ..................................................................................................................................................... 33
Measured values LT status Grid status ................................................................................................ 33

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo Series and is the answer not in the manual?

Fronius Primo Series Specifications

General IconGeneral
EfficiencyUp to 98.1%
Protection RatingIP65
Operating Temperature Range-25°C to +60°C
Frequency50 / 60 Hz
DC input voltage range80 - 600 V
ModelPrimo Series
TypeTransformerless
Power Classes3.0 kW to 8.2 kW
Communication InterfacesWLAN, Ethernet, RS485
Weight21.5 kg
Max. apparent AC power8, 200 VA
AC voltage range150 - 280 V
MPP voltage range240 - 480 V
Warranty5 years
Dimensions645 x 431 x 204 mm