9
EN-US
The manufacturer is not responsible for any damage resulting from improper use.
All warranty claims are considered void in such cases.
Proper use also means
- carefully reading and obeying all the instructions and safety and danger notices in the
operating instructions
- carrying out all the specified inspection and servicing work
- installation as per operating instructions.
When configuring the photovoltaic system, make sure that all photovoltaic system compo-
nents are operating completely within their permitted operating range.
All measures recommended by the solar module manufacturer for maintaining solar mod-
ule properties must be followed.
Utility company regulations regarding grid power feed must be followed.
Information on
"Field Adjustable
Trip Points" and
"Advanced Grid
Features"
The inverter is equipped with field adjustable trip points and advanced grid features. For
further information, please contact Fronius technical support at the following e-mail ad-
dress: pv-us-support@fronius.com.
FCC / RSS Com-
pliance
Insulation Moni-
toring
The inverter is fitted with the following safety function as required by UL 1741 and the Na-
tional Electrical Code:
FCC
This device corresponds to the limit values for a digital device of class B in
accordance with Part 15 of the FCC regulations. The limit values should pro-
vide adequate protection against harmful interference in homes. This device
creates and uses high frequency energy and can interfere with radio com-
munications when not used in accordance with the instructions. However,
there is no guarantee against interference occurring in a particular installa-
tion.
If this device interferes with radio or television reception when turning the de-
vice on and off, it is recommended that the user solve this with one or more
of the following measures:
- adjust or reposition the receiving antenna
- increase the distance between the device and the receiver
- connect the device to another circuit, which does not include the receiv-
er
- for further support, please contact the retailer or an experienced radio/
TV technician.
Industry Canada RSS
The device corresponds to the license-free Industry Canada RSS stan-
dards. Operation is subject to the following conditions:
(1) The device may not cause harmful interference
(2) The device must accept any interference received, including interfer-
ence that may cause undesired operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo Series and is the answer not in the manual?

Fronius Primo Series Specifications

General IconGeneral
EfficiencyUp to 98.1%
Protection RatingIP65
Operating Temperature Range-25°C to +60°C
Frequency50 / 60 Hz
DC input voltage range80 - 600 V
ModelPrimo Series
TypeTransformerless
Power Classes3.0 kW to 8.2 kW
Communication InterfacesWLAN, Ethernet, RS485
Weight21.5 kg
Max. apparent AC power8, 200 VA
AC voltage range150 - 280 V
MPP voltage range240 - 480 V
Warranty5 years
Dimensions645 x 431 x 204 mm

Related product manuals