3000 CONTROLLER USER GUIDE
18
SYSTEM
TEMPR
FORMAT
(Global)
2-8. Press to scroll choices: F for Fahrenheit; C for Celsius (Default
is set at factory).
Press to advance. Far left controller only.
2-9. Use numbered keys to select a temperature from 100° F (38° C) to
180° F (82° C) (Default is 180°F) (82°C).This is the temperature for the
fryer to exit the melt cycle.
Press to advance. Far left controller only.
2-10. Use numbered keys to select a setback temperature. (Default is 250°F)
(121°C). This is the temperature during cool mode.
Press to advance. Far left controller only.
2-11. Use numbered keys to select a number of minutes the frypot sits idle
before going to cool mode. (Default is 0, disabling this feature).
Press to advance.
2-12. Press to scroll choices NONE, BULK, JIB. (Default is set at
factory).
Press to advance. Far left controller only.
2-13. Press to scroll choices NONE, BULK. (Default is set at factory).
Press to advance. Far left controller only.
2-14. Press to scroll choices YES and NO. Press to advance
(Default is set at factory). Far left controller only.
2-15. Press to scroll choices DISABLED and ENABLED. This is an
alarm that locks out the fryer if it does not heat properly (Default is
DISABLED).
Press to advance. Far left controller only.
2-16. This feature only applies to units that have basket lifts.
Press to scroll choices DISABLED and ENABLED. (Default is
ENABLED).
Press to advance. Far left controller only.
2-17. Press to scroll choices AUTO and MANUAL. (Default is AUTO).
Cancels alarm automatically after a few seconds.
Press to advance.
Press button to lock-in the vat set-up and to return the controller to OFF.
3. Vat Set Up: Time/Date
NOTE: Global system settings are only available on the far left controller.
3-1. Press until PRODUCT SETUP is displayed.
3-2. Press to scroll to VAT SETUP and press .