3000 CONTROLLER USER GUIDE
41
Appendix B: 3000 Controller Error Log Codes
CODE
ERROR MESSAGE
EXPLANATION
E03
ERROR TEMP PROBE FAILURE
TEMP Probe reading out of range.
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than
410°F (210°C), or in CE countries, 394°F
(202°C).
E06
HEATING FAILURE
A component has failed in the high limit
circuit such as controller, interface board,
contactor or open-high limit.
E08
ERROR ATO BOARD
AT board connection lost; ATO board failure.
E17
ERROR ATO PROBE
ATO RTD reading out of range.
E20
INVALID CODE LOCATION
SD Card removed during update.
E25
RECOVERY FAULT
Recover time exceeded maximum time limit.
Recovery time should not exceed 1:40 for
electric or 2:25 for gas.
E28
HIGH TEMP ALARM
Oil temperature has risen 40°F (4.4°C)
higher than setpoint. If temperature
continues to rise, high limit feature will shut
the burner off when temperature reaches
425°F (218°C).