Preparing Your Installation Site
20
wireless at the speed of light …………….
SO
NAbeam E-Series Installation Manual
SONAbeam Fiber Requirements
Your SONAbeam E-Series terminal employs an industry standard small form-factor
pluggable (SFP) transceiver for network traffic. The following Interface options are
available from the factory:
FIBER:
10-0056A (155-E & 1250-E)
Description: 1000-Base-LX, Single mode fiber, LC terminated, 1310nm
TX output power: -9 dBm (min) -3 dBm (max)
RX input power: -21 dBm (min) -3 dBm (max)
10-0057A (155-E & 1250-E)
Description: 1000-Base-SX, Multimode fiber, LC terminated, 850nm
TX output power: -9 dBm (min) -3 dBm (max)
RX input power: -17 dBm (min) 0 dBm (max)
10-0084A (2500-E)
Description: 2.5 Gbps SFP, Single mode fiber, LC terminated, 1310nm
TX output power: -5 dBm (min) 0 dBm (max)
RX input power: -18 dBm (min) -3 dBm (max)
10-0085A (2500-E)
Description: 2.5 Gbps SFP, Multimode fiber, LC terminated, 850nm
TX output power: -10 dBm (min) -3 dBm (max)
RX input power: -18 dBm (min) -3 dBm (max)
COPPER:
10-0058A (1250-E)
Description: 1000-BaseT, RJ45 terminated, copper
10-0082A (155-E)
Description: 100-BaseT, RJ45 terminated, copper
WARNING!
When providing your own SFP transceiver, verify its product compatibility with
fSONA Networks.