5.1 PLC Connection 5-5
5.1.3 KV10/24 CPU
Communication Setting
Editor
Communication setting
(Underlined setting: default)
PLC
No particular setting is necessary on the PLC.
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Item Setting Remarks
Connection Mode 1:1
/ Multi-link2 / Multi-link2 (Ethernet)
Signal Level RS-232C
Baud Rate 9600 / 19200 / 38400 / 57600
bps
If a baud rate higher than 57600 bps is set,
communication is performed at 9600 bps.
Data Length 8 bits
Stop Bit 1 bit
Parity Even
Targe t Port No. 0
Device Memory TYPE Remarks
DM (data memory) 00H
CH (input/output/internal auxiliary relay) 01H
TC (timer/current value) 02H
CC (counter/current value) 03H
TS (timer/set value) 04H
CS (counter/set value) 05H
T(timer/contact) 06H
C (counter/contact) 07H
TM (temporary data memory) 08H