9.2 Temperature Controller/Servo/Inverter Connection 9-61
PLC_CTL
Macro command “PLC_CTL F0 F1 F2”
Contents F0 F1 (= $u n) F2
Writing running
frequency (EEPROM)
1 - 8
(PLC1 - 8)
n
Station number
3n + 1
Command: 00EEH
n + 2
Running frequency
Writing running
frequency (RAM)
1 - 8
(PLC1 - 8)
n
Station number
3n + 1
Command: 00EDH
n + 2
Running frequency
All alarms clear
1 - 8
(PLC1 - 8)
n
Station number
2
n + 1
Command: 00F4H
Operation command
1 - 8
(PLC1 - 8)
n
Station number
3
n + 1
Command: 00FAH
n + 2
0000H: Stop
0002H: Normal rotation (STF)
0004H: Reverse rotation (STR)
All parameter clear
1 - 8
(PLC1 - 8)
n
Station number
3
n + 1
Command: 00FCH
n + 2
Pr.
Data
Communication
Pr.
Calibration Other Pr.
00ECH
00F3H
00FFH
9696H
9966H
5A5AH

55AAH
Inverter reset
1 - 8
(PLC1 - 8)
n
Station number
2
n+1
Command: 00FDH

Table of Contents