9-68 9. MITSUBISHI ELECTRIC
Set the target device memory on the [Device Input] dialog.
RAM: Stored in RAM
EEPROM: Stored in RAM + EEPROM
Indirect Device Memory Designation
Address No. 0 to 65535
* Expansion code
PLC_CTL
Macro command “PLC_CTL F0 F1 F2”
Return data: Data stored from controller to V series
06A (basic setting parameters upper limit) 1EH Double-word, read only
06B (gain/filter parameters upper limit) 1FH Double-word, read only
06C (extension setting parameters upper limit) 20H Double-word, read only
06D (I/O setting parameters upper limit) 21H Double-word, read only
F06A (basic setting parameters upper limit) 22H Real number, read only
F06B (gain/filter parameters upper limit) 23H Real number, read only
F06C (extension setting parameters upper limit) 24H Real number, read only
F06D (I/O setting parameters upper limit) 25H Real number, read only
07A (basic setting parameters lower limit) 1EH Double-word, read only
07B (gain/filter parameters lower limit) 1FH Double-word, read only
07C (extension setting parameters lower limit) 20H Double-word, read only
07D (I/O setting parameters lower limit) 21H Double-word, read only
F07A (basic setting parameters lower limit) 22H Real number, read only
F07B (gain/filter parameters lower limit) 23H Real number, read only
F07C (extension setting parameters lower limit) 24H Real number, read only
F07D (I/O setting parameters lower limit) 25H Real number, read only
S08A (basic setting parameters symbol) 2EH Read only
S08B (gain/filter parameters symbol) 2FH Read only
S08C (extension setting parameters symbol) 30H Read only
S08D (I/O setting parameters symbol) 31H Read only
09A (write enable/disable of basic setting parameters) 32H Read only
09B (write enable/disable of Gain/filter parameters) 33H Read only
09C (write enable/disable of Extension setting parameters) 34H Read only
09D (write enable/disable of I/O setting parameters) 35H Read only
Device Memory TYPE Remarks
15 8 7 0
n+0
Models Device Type
n+1
Address No.
n+2
Expansion code * Bit designation
n+3
00 Station number
15 8
000000
Expansion bits
0: 0 to 15 bits
1: 16 to 31 bits
0: RAM
1: RAM+EEPROM
Contents F0 F1 (= $u n) F2
Software version
1 - 8
(PLC1 - 8)
n
Station number
3
n + 1
Command: 0002H
n + 2
Data No. 0070H
n+3 to n+10
Software version