15-64 15. Panasonic
KW1M-R(AKW1131/AKW1131K)
(Underlined setting: default)
Stop bit: 1 (fixed)
* Use system program version 2.2 or later.
KW2G/KW2G-H
(Underlined setting: default)
KW4M
(Underlined setting: default)
Protocol: MEWTOCOL, stop bit: 1 (fixed)
Terminal station setting
Mode Display Item Setting
MODE 3
FORM Wired/wireless setting mode WIRED
PROT Protocol setting mode MEWT: MEWTOCOL
NO. Station number setting mode 1 to 99
SPD Baud rate setting mode
4800: 4800 bps
9600: 9600 bps
19200: 19200 bps
38400: 38400 bps
FMT
Communication format
setting mode
8bit-o: data length 8 bits, odd parity
7bit-n: data length 7 bits, without parity
7bit-E: data length 7 bits, even parity
7bit-o: data length 7 bits, odd parity
8bit-n: data length 8 bits, without parity
8bit-E: data length 8 bits, even parity
Mode Display Item Setting
MODE 3
PROT Protocol setting mode MEWT: MEWTOCOL
NO Station number setting mode 1 to 99
SPD Baud rate setting mode
4800: 4800 bps
9600: 9600 bps
19200: 19200 bps
38400: 38400 bps
FMT
Communication format
setting mode
8bit-o: data length 8 bits, odd parity
7bit-n: data length 7 bits, without parity
7bit-E: data length 7 bits, even parity
7bit-o: data length 7 bits, odd parity
8bit-n: data length 8 bits, without parity
8bit-E: data length 8 bits, even parity
STOP Stop bit setting mode
1: 1 bit
2: 2 bits
Mode Display Item Setting
MODE 3
NO. Station setting mode 1
to 99
SPD Baud rate setting mode
4800: 4800 bps
9600: 9600 bps
19200: 19200 bps
38400: 38400 bps
FMT
Communication format
setting mode
8bit-o: data length 8 bits, odd parity
7bit-n: data length 7 bits, without parity
7bit-E: data length 7 bits, even parity
7bit-o: data length 7 bits, odd parity
8bit-n: data length 8 bits, without parity
8bit-E: data length 8 bits, even parity
Slide Switch Item Setting
Terminal station setting
General : General s tation
Terminal: Terminal station
GeneralTerminal