1-41
Section 1 Specications
(2) Example of a system in which expansion units are connected to a main unit (60 points)
(3) Example of a system in which expansion units are connected to a main unit (32 points)
%IW0.0
%IW0.1
%IW0.2
%QW0.4
%QW0.5
%IW1.0
%QW1.1
%IW2.0
%QW2.1
%QW3.0
%IX0.0.0 to %IX0.0.15
%IX0.1.0 to %IX0.1.15
%IX0.2.0 to %IX0.2.3
%QX0.4.0 to %QX0.4.15
%QX0.5.0 to %QX0.5.7
%IX1.0.0 to %IX1.0.13
%QX1.1.0 to %QX1.1.9
%IX2.0.0 to %IX2.0.3
%QX2.1.0 to %QX2.1.3
%QX3.0.0 to %QX3.0.15
0F
Input: 36 points
Input: 14 points
Input:
4 points
Output:
4 points
Output: 10 points
Main unit with 60 points
Unit No. 0
Input: 36 points
output: 24 points
Output: 24 points
Output: 16 points
Expansion
right side unit
Unit No. 3
Output: 16 points
Expansion
right side unit
Unit No. 2
Input: 4 points
output: 4 points
Expansion
right side unit
Unit No. 1
Input: 14 points
output: 10 points
(Word address) (Bit address)
%IW0.0
%IW0.1
%QW0.4
%IW1.0
%IW2.0
%IW2.1
%IW2.2
%IW2.3
%QW2.4
%QW2.5
%IX0.0.0 to %IX0.0.15
%IX0.1.0 to %IX0.1.3
%QX0.4.0 to %QX0.4.11
%IX1.0.0 to %IX1.0.7
0F
Input: 20 points
Input: 8 points
Input: 4 words
Main unit with 32 points
Unit No. 0
Input: 20 points
output: 12 points
Output: 12 points
Output: 2 words
Expansion
right side unit
Unit No. 2
Input: 4 words
output: 2 words
Expansion
right side unit
Unit No. 1
Input: 8 points
(Word address) (Bit address)