EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Table
1-6
  
Workflow
when
connecting
the
PCI
expansion
unit
(continued)
Step
(work
time
(*1)) Work
description Referenc e
3 Prepare
the
necessary
tools/
information
for
installation.
"3.1
Preparing
the
Necessary
Tools/Information
for
Installation"
Required
4 Confirm
the
delivered
components. "3.2.4
Confirming
the
delivered
components
of
the
PCI
expansion
unit"
Required
5 Install
the
rack. See
the
manual
for
each
rack.
"3.3.2
Securing
the
rack"
Required
6Mount
the
PCI
expansion
unit
in
the
rack.
"3.4.3
Mounting
the
PCI
expansion
unit
in
a
rack"
Required
7If
there
are
optional
components,
mount
them
on
the
PCI
expansion
unit.
"3.5.3
Mounting
optional
components
in
the
PCI
expansion
unit"
Optional
(*3)
8
Connect
the
link
ca ble
and
man agem ent
cable
to
the
PCI
expansion
unit.
Attach
the
core
to
the
power
cord,
and
connect
the
power
cord
to
the
power
supply
unit.
"5.3
Connecting
Cables
to
the
PCI
Expansion
Unit"
Required
(*4)
Initial
diagnosis
(approx.
45
minutes)
9 Connect
the
system
management
terminal
to
the
chassis
that
has
the
PCI
expansion
unit
connected
to
it.
"6.1
Connecting
the
System
Management
Terminal
to
the
Chassis"
Required
10 Turn
on
the
input
power. "6.2.2
Turning
on
the
input
power
and
starting
the
XSCF"
Required
11 Log
in
to
the
SPARC
M10
system
connected
to
the
PCI
expansion
unit.
"6.3
Logging
In
to
the
XSCF" Required
12 Perform
an
initial
diagnosis
test
on
the
physical
system
board
(PSB).
"6.7
Performing
a
Diagnosis
Test" Required
13 Check
the
status
of
mounted
components.
"6.8
Checking
the
Component
Status"
Required
*1
Average
work
time
*2
Time
required
for
mounting
optional
components
is
not
included.
*3
If
the
optional
components
are
ordered
together
with
the
chassis,
they
are
shipped
mounted
to
the
chassis.
*4
It
is
assumed
that
a
link
card
is
installed
in
the
chassis
to
which
the
PCI
expansion
unit
is
to
be
connected.
If
a
link
card
is
installed
on
site,
see
"Chapter
10
Maintaining
the
Link
Cards"
in
the
PCI
Expansion
Unit
for
Fujitsu
M10/SPARC
M10
Systems
Service
Manual.
Points
to
note
on
configurations
with
the
PCI
expansion
unit
connected
SPARC
M10-1
In
either
of
the
following
cases,
the
logical
domain
configuration
of
a
physical
Chapter
1
 
Understanding
the
Installation
Flow 13

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals