XSCF>
version
-c
xcp
BB#00-XSCF#0
(Master)
XCP0
(Current) :
2042
XCP1
(Reserve) :
2042
BB#01-XSCF#0
(Standby)
XCP0
(Current) :
2042
XCP1
(Reserve) :
2042
BB#02-XSCF#0
XCP0
(Current) :
2042
XCP1
(Reserve) :
2042
BB#03-XSCF#0
XCP0
(Reserve) :
2042
XCP1
(Current) :
2042
Note
-
Setting
the
altitude
in
the
system
makes
it
possible
to
detect
abnormal
intake
temperatures
early.
If
the
altitude
of
the
installation
location
is
unknown,
set
a
high
altitude.
Abnormal
temperatures
can
be
detected
from
abnormal
CPU
temperatures,
for
example,
even
if
no
altitude
is
set
in
the
system.
This
prevents
critical
damage
to
the
system.
XSCF>
showaltitude
0m
XSCF>
setaltitude
-s
altitude=100
100m
3.
Execute
the
version
command,
and
confirm
that
the
firmware
version
of
each
chassis
matches.
6.5 Checking
the
Altitude
Setting
This
section
describes
the
procedure
for
checking
and
setting
the
altitude
of
the
installation
location.
The
setting
in
the
factory
default
settings
is
0
m.
Check
the
setting
value,
and
change
it
as
needed.
1.
Execute
the
showaltitude
command.
The
following
example
displays
the
system
altitude.
The
factory
default
setting
is
"0
m".
2.
If
the
altitude
setting
is
correct,
skip
step
2
and
subsequent
steps.
To
change
the
altitude,
execute
the
setaltitude
command.
The
setting
is
in
units
of
100
m,
and
values
less
than
100
m
are
rounded
up.
The
following
example
sets
the
altitude
to
100
m.
3.
Execute
the
rebootxscf
command
to
reflect
the
setting.
If
you
are
also
Chapter
6
 
Performing
an
Initial
System
Diagnosis 185

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals