Page #248 background image
Pattern Rem oval
description Reference
ARemoval
of
the
SPARC
M10-4S
mounted
in
an
expansion
rack
Example:
From
the
16BB
configuration
to
the
14BB
configuration,
and
from
the
8BB
configuration
to
the
6BB
configuration
"10.2
Removing
the
SPARC
M10-4S"
B
(1) Removal
of
the
SPARC
M10-4S
with
direct
connections
between
chassis
Example:
From
the
4BB
configuration
to
the
3BB
configuration,
and
from
the
4BB
configuration
to
the
2BB
configuration
"10.2
Removing
the
SPARC
M10-4S"
B
(2) Release
of
the
connections
between
the
chassis
in
an
existing
multiple-BB
configuration
(direct
connections
between
chassis)
to
change
every
chassis
to
the
1BB
configuration
Example:
From
the
4BB
configuration
to
the
1BB
configuration
"10.2.3
Removing
the
server
after
stopping
all
the
physical
partitions
(PPARs)"
CRemoval
of
expansion
rack
2,
and
decrease
of
the
number
of
SPARC
M10-4S
units
to
four
or
less
Example:
From
the
16BB
configuration
(connections
through
crossbar
boxes)
to
the
4BB
configuration
(connections
through
crossbar
boxes)
"10.3
Removal
of
Expansion
Rack
2,
and
Decrease
in
the
Number
of
SPARC
M10-4S
Units
to
Four
or
Less"
In
the
above
figures,
"BB"
indicates
the
SPARC
M10-4S
and
"XBBOX"
indicates
a
crossbar
box.
8.3.2 Points
of
concern
during
removal
Before
removing
the
SPARC
M10-4S,
check
the
following
items,
which
are
points
of
concern.
â– 
If
you
stop
a
PPAR
and
remove
the
SPARC
M10-4S
belonging
to
the
PPAR,
logical
domain
configuration
information
is
switched
to
factory-default
the
next
time
that
the
PPAR
is
powered
on.
In
that
case,
reconfigure
the
logical
domains
by
referring
to
the
logical
domain
configuration
information
in
the
XML
file
saved
at
the
system
configuration
time.
â– 
Multiple
SPARC
M10-4S
units
cannot
be
released
from
the
system
by
using
the
initbb
command
at
the
same
time.
Do
this
work
on
one
unit
at
a
time.
â– 
The
serial
number
of
the
chassis
of
either
the
master
XSCF
or
standby
XSCF
is
used
as
the
system
serial
number.
If
the
serial
number
of
the
standby
chassis
is
being
used
as
the
system
serial
number,
the
initbb
command
cannot
release
the
standby
chassis.
In
this
case,
execute
the
switchscf
command
to
switch
the
master
XSCF.
â– 
For
the
initialization
of
the
chassis
of
the
master
XSCF,
perform
that
work
at
the
end.
Execute
the
restoredefaults
-c
factory
command
to
return
to
the
factory
defaults,
including
the
CPU
Activation
key
information.
Perform
this
work
with
a
serial
connection
to
the
master
XSCF.
For
XCP
2041
or
later,
execute
the
restoredefaults
-c
factory
-r
activation
command.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015234

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals