Fujitsu M10 - 10.3 Removal of Expansion Rack 2, and Decrease in the Number of SPARC M10-4 S Units to Four or Less

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XSCF>
showbbstatus
BB#00
(Master)
Note
-
If
the
serial
number
of
the
target
chassis
is
being
used
as
the
system
serial
number,
the
initbb
command
cannot
release
the
chassis.
In
this
case,
execute
the
switchscf
command
to
switch
the
master
XSCF.
XSCF>
poweroff
-y
-a
PPAR-IDs
to
power
off:00,01,02,03,04,05,06,07,08,09,10,11
Continue?
[y|n]:
y
00:Powering
off
01:Powering
off
02:Powering
off
03:Powering
off
04:Powering
off
05:Powering
off
06:Powering
off
07:Powering
off
08:Powering
off
09:Powering
off
10:Powering
off
11:Powering
off
10.3 Removal
of
Expansion
Rack
2,
and
Decrease
in
the
Number
of
SPARC
M10-4S
Units
to
Four
or
Less
This
section
describes
the
procedure
to
remove
the
expansion
rack
2
and
set
four
or
less
SPARC
M10-4S
on
the
expansion
rack
1
(connection
via
crossbar
box).
This
procedure
corresponds
to
pattern
C
in
Figure
8-3.
You
need
to
stop
the
system
during
this
work.
 
For
details
on
the
XSCF
commands
executed
in
each
step,
see
the
Fujitsu
M10/SPARC
M10
Systems
XSCF
Reference
Manual.
1.
Log
in
to
the
master
XSCF.
Execute
the
showbbstatus
command
to
confirm
that
the
XSCF
to
which
you
have
logged
in
is
the
master
XSCF.
If
it
is
a
standby
XSCF,
retry
to
log
in
to
the
master
XSCF.
2.
Execute
the
show hardconf
command,
and
confirm
the
chassis
serial
number
of
the
system
board
(PSB)
targeted
for
release.
For
details,
see
"A.2.1
Checking
the
component
status."
3.
Execute
the
poweroff
command
to
stop
all
the
physical
partitions.
Chapter
10
 
Removing
a
System
with
a
Building
Block
Configuration 293

Table of Contents

Other manuals for Fujitsu M10