EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
XSCF>

diagxbu

-y

-b

XX

-t

YY

[-t

zz]

XSCF>

diagxbu

-y

-b

02

-t

00

-t

01
XBU

diagnosis

is

about

to

start,

Continue?[y|n]

:y

Power

on

sequence

started.

[7200sec]


0.....

30.....

60.....

90..end

XBU

diagnosis

started.

[7200sec]


0.....

30.....

60.....

90.....120.....150.....180.....210.....240.....|

270.....300.....330.....360.....390.....420.....450.....480.....510.....\

540.....570.....600.....630.....660.....690.....720.....750.....780.....|

810.....840.....870.....900.....930.....960.....990.....1020.....1050.....\

1080.....1110...end

completed.

Power

off

sequence

started.

[1200sec]


0.....

30.....

60.....

90.....120.....150.....180.....210...end

completed.
XSCF>

showlogs

error
b.
Execute
the
diagxbu
command
to
check
the
cables.
Specify
the
BB-ID
of
the
installed
BB
in
XX.
(*2)
indicates
this
BB-ID
checked
in
step
b.
In
YY,
specify
the
BB-ID
of
the
BB
incorporated
into
the
physical
partition.
(*1)
indicates
this
BB-ID
checked
in
step
b.
The
following
example
performs
a
diagnosis
between
the
installed
BB#02
and
the
incorporated
BB#00
and
BB#01
in
PPAR#0.
c.
Execute
the
showlogs
error
command,
and
confirm
that
no
error
is
displayed.
If
an
error
is
displayed,
see
"A.2.2
Checking
the
contents
of
logs."
d.
Execute
the
showhardconf
command
to
check
the
configuration,
status,
and
quantities.
For
details,
see
"6.8
Checking
the
Component
Status."
7.
If
the
installation
expanded
the
1BB
configuration
to
a
multiple-BB
configuration,
configure
the
XSCF
network.
For
details,
see
"7.5.2
Setting
an
Ethernet
(XSCF-LAN)
IP
address"
and
"7.5.3
Setting
a
takeover
IP
address."
After
configuration,
execute
the
applynetwork
command
to
apply
the
settings,
and
confirm
that
they
were
reflected.
Then,
execute
the
rebootxscf
command
to
complete
settings,
and
go
to
the
next
step.
For
details
on
the
procedure,
see
"7.5.6
Applying
network
settings."
Since
you
are
expanding
the
2BB
configuration
to
the
3BB
configuration,
this
work
is
not
necessary.
8.
To
configure
memory
mirroring
for
the
insta lled
SPARC
M10-4S,
set
memory
mirror
mode.
For
details,
see
"7.6
Configuring
Memory
Mirroring."
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015256

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals