XSCF>

testsb

-v

-p

-s

-a

-y
Initial

diagnosis

is

about

to

start,

Continue?[y|n]

:y
SB

power

on

sequence

started.
POST

Sequence

01

Banner
Note
-
A
cable
check
with
the
diagxbu
command
is
not
necessary
because
this
command
with
the
-a
option
specified
performs
a
diagnosis
test
on
all
the
mounted
system
boards
(PSBs).
XSCF>

showlogs

error
-s:
Executes
the
"show-devs"
command
of
OpenBoot
PROM
and
displays
the
results
while
a
diagnosis
is
being
processed
-a:
Diagnoses
all
the
mounted
PSBs
-y:
Automatically
responds
with
"y"
to
a
query
If
an
error
is
displayed,
see
"A.2.4
Checking
diagnosis
results."
16.
Execute
the
showlogs
error
command,
and
confirm
that
no
error
is
displayed.
If
an
error
is
displayed,
see
"A.2.2
Checking
the
contents
of
logs."
17.
Execute
the
showhardconf
command
from
the
master
XSCF
to
check
the
configuration,
statu s,
and
quantities.
For
details,
see
"6.8
Checking
the
Component
Status."
18.
If
the
installation
expanded
the
1BB
configuration
to
a
multiple-BB
configuration,
configure
the
XSCF
network.
For
details,
see
"7.5.2
Setting
an
Ethernet
(XSCF-LAN)
IP
address"
and
"7.5.3
Setting
a
takeover
IP
address."
After
configuration,
execute
the
applynetwork
command
to
apply
the
settings,
and
confirm
that
they
were
reflected.
Then,
execute
the
rebootxscf
command
to
complete
settings,
and
go
to
the
next
step.
For
details
on
the
procedure,
see
"7.5.6
Applying
network
settings."
19.
To
configure
memory
mirroring
for
the
insta lled
SPARC
M10-4S,
set
memory
mirror
mode.
For
details,
see
"7.6
Configuring
Memory
Mirroring."
20.
Creat e
physical
partition
configuration
information .
For
details,
see
"7.7
Creating
a
Physical
Partition
Configuration
List
(PCL)."
21.
Add
the
system
board
(PSB)
to
the
physical
partition.
For
details,
see
"7.8
Assigning
a
System
Board
(PSB)
to
a
Physical
Partition
(PPAR)."
22.
Check
the
CPU
Activation
key
information,
and
assign
CPU
resources
to
the
physical
partition.
For
details,
see
"7.11
Registering
a
CPU
Activation
Key."
23.
Execute
the
poweron
command
to
start
the
system.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015264

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals