EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #287 background imageLoading...
Page #287 background image
XSCF>

showboards

-a
PSB

PPAR-ID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault
----

------------

-----------

----

----

----

-------

--------
00-0

SP

Available

n

n

n

Passed

Normal
01-0

SP

Available

n

n

n

Passed

Normal
02-0

SP

Available

n

n

n

Passed

Normal
03-0

SP

Available

n

n

n

Passed

Normal
XSCF>

initbb

-b

bb_id
XSCF>

initbb

-b

3
You

are

about

to

initializ e

BB/XB-Box.
NOTE

the

following.
1.

BB/XB-Box

is

excluded

from

the

system

and

halted.
2.

PPAR-ID

of

the

same

value

as

BB-ID

becomes

invalid.
Continue?

[y|n]

:
y
Note
-
After
the
execution
of
the
initbb
command,
the
target
chassis
is
released
from
the
system
and
enters
the
stopped
state.
Do
not
disconnect
the
power
cords
or
various
cables
until
the
XSCF
STANDBY
LED
on
the
panel
and
the
rear
READY
LED
of
the
target
chassis
are
off.
Note
-
For
the
initialization
of
the
chassis
of
the
master
XSCF,
perform
that
work
at
the
end.
Execute
the
restoredefaults
-c
factory
command
to
return
to
the
factory
defaults,
including
the
CPU
Activation
key
information.
Perform
this
work
with
a
serial
connection
to
the
master
XSCF.
For
XCP
2041
or
later,
execute
the
restoredefaults
-c
factory
-r
activation
command.
The
key
must
be
reinstalled
at
initial
setup
of
the
XSCF
after
installation.
In
the
following
example,
system
boards
00-0,
01-0,
02-0,
and
03-0
are
in
the
system
board
pool.
7.
Execute
the
initbb
command
from
the
master
XSCF
to
release
the
target
SPARC
M10-4S
from
the
system
and
initialize
it.
In
bb_id,
specify
the
ID
(BB-ID)
identifying
the
chassis.
The
following
example
releases
BB#03
from
the
system
and
initializes
it.
8.
Remove
the
power
cords
from
the
power
supply
units
of
the
target
SPARC
M10-4S.
9.
Remove
the
XSCF
BB
control
cables
from
the
target
SPARC
M10-4S.
10.
Remove
the
crossbar
cables
from
the
target
SPARC
M10-4S.
11.
If
the
removal
changes
the
configuration
to
the
1BB
configuration,
remove
the
XSCF
DUAL
control
cable.
12.
Remove
the
target
SPARC
M10-4S
from
the
rack.
Remove
the
SPARC
M10-4S
from
the
rack
by
reversing
the
mounting
procedure.
Chapter
9
 
Installing
a
System
with
a
Building
Block
Configuration 273

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals