EasyManuals Logo

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
frequency
indicated
on
the
electrical
rating
label
affixed
to
the
chassis.
Make
sure
to
wear
a
wrist
strap
when
handling
the
hard
disk
drive,
motherboard
unit/CPU
memory
unit,
or
other
printed
circuit
boards.
Make
sure
to
use
grounded
power
outlets.
Do
not
make
mechanical
or
electrical
modifications
to
the
chassis.
We
do
not
take
responsibility
for
regulatory
compliance
of
a
modified
chassis.
Do
not
disconnect
a
power
cord
from
the
chassis
while
the
power
is
on.
Safety
precautions
regarding
racks
Racks
must
be
fixed
to
the
floor,
ceiling,
or
nearest
frame.
The
quakeresistant
options
kit
may
be
supplied
with
the
racks.
The
use
of
the
quakeresistant
options
kit
prevents
the
rack
from
toppling
over
when
the
chassis
is
pulled
out
from
the
slide
rails
for
installation
or
maintenance.
In
the
following
cases,
a
safety
evaluation
must
be
performed
by
a
service
engineer
before
installation
or
maintenance.
-
If
the
quakeresistant
options
kit
is
not
supplied
and
the
rack
is
not
fixed
with
bolts
to
the
floor,
a
service
engineer
confirms
the
safety
of
the
rack,
such
as
by
verifying
that
it
does
not
topple
over
when
the
chassis
is
pulled
out
from
the
slide
rails.
-
If
the
rack
is
mounted
on
a
raised
floor,
a
service
engineer
confirms
that
the
floor
can
withstand
the
load
when
the
chassis
is
pulled
out
from
the
slide
rails.
Fix
the
rack
to
the
concrete
floor
beneath
the
raised
floor
by
using
the
original
mounting
kit
that
serves
this
purpose.
If
multiple
chassis
are
mounted
in
the
rack,
perform
maintenance
on
one
chassis
at
a
time.
Safety
precautions
regarding
installation
work
With
this
chassis
installed
in
a
closed
or
multi-unit
rack
assembly,
the
ambient
temperature
inside
the
rack
operating
environment
may
be
greater
than
the
ambient
room
temperature.
Therefore,
consideration
must
be
given
to
installing
the
chassis
in
an
environment
compatible
with
the
manufacturer's
maximum
rated
ambient
temperature.
-
Consideration
of
air-conditioning
adjustments,
such
as
with
air
circulation,
is
needed
to
prevent
the
ambient
temperature
inside
the
rack
from
exceeding
the
maximum
ambient
operating
temperature
of
this
chassis.
-
Maximum
ambient
operating
temperature
of
this
chassis:
35°C
The
installation
of
the
chassis
in
a
rack
should
allow
for
sufficient
air
flow
for
the
chassis
to
operate
safely.
-
This
chassis
has
ventilation
slits
at
the
front
and
rear
of
the
chassis.
-
To
prevent
overheating,
do
not
cover
or
close
these
ventilation
slits.
The
mounting
of
the
chassis
in
the
rack
should
not
create
any
hazardous
condition
due
to
uneven
mechanical
loading.
To
keep
the
entire
rack
stable,
fix
the
rack
to
the
wall
or
floor
by
suitable
means.
-
Be
careful
not
to
injure
yourself
or
others
when
installing
the
chassis
in
the
rack.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
July
201518

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals