/packages/dropins
/packages/terminal-emulator
/packages/disk-label
/packages/deblocker
/packages/SUNW,probe-error-handler
/packages/SUNW,builtin-drivers
PSB
Test
Fault
----
-------
--------
00-0
Passed
Normal
XSCF#
XSCF>
diagxbu
-y
-b
bb_id
-t
target_bb
XSCF>
diagxbu
-y
-b
bb_id
-p
ppar_id
diagxbu
command
diagxbu
is
a
command
that
diagnoses
the
crossbar
cables
and
crossbar
units
connected
to
the
specified
SPARC
M10-4S
chassis.
A
crossbar
unit
is
mounted
in
a
SPARC
M10-4S
chassis
or
crossbar
box
and
connected
by
crossbar
cables.
To
execute
the
diagxbu
command,
you
need
to
specify
the
SPARC
M10-4S
chassis
where
the
diagnosis
begins,
and
also
the
SPARC
M10-4S
chassis
connected
as
the
communication
destination.
If
the
diagnosis
results
show
that
a
failure
occurred
in
the
crossbar
cables
and
crossbar
units,
you
can
check
it
with
the
showlog
error
command.
Also,
if
a
crossbar
unit
is
degraded,
you
can
check
it
with
the
showstatus
command.
 
The
two
ways
of
using
diagxbu
are
as
follows:
specify
the
BB-ID
of
the
cable
connection
destination;
or
specify
the
PPAR-ID
of
the
cable
connection
destination.
How
to
specify
the
BB-ID
of
the
cable
connection
destination
If
a
system
board
(PSB)
in
the
chassis
connected
by
crossbar
cables
has
not
been
incorporated
into
a
physical
partition
(PPAR),
or
if
the
power
to
the
incorporating
physical
partition
is
off,
specify
the
BB-ID
of
the
cable
connection
destination.
-
bb_id:
Enter
the
BB-ID
of
the
chassis
where
the
diagnosis
begins.
-
target_bb:
Enter
the
BB-ID
of
the
chassis
connected
by
the
crossbar
cables
(multiple
BB_IDs
can
be
specified).
How
to
specify
the
PPAR-ID
of
the
cable
connection
destination
If
the
system
board
(PSB)
in
the
chassis
connected
by
crossbar
cables
has
been
incorporated
into
a
physical
partition
and
the
power
to
the
physical
partition
is
on,
specify
the
PPAR_ID
of
the
cable
connection
destination.
-
bb_id:
Enter
the
BB-ID
of
the
chassis
where
the
diagnosis
begins.
-
ppar_id:
Enter
the
PPAR_ID
of
the
chassis
connected
by
crossbar
cables
(only
one
PPAR_ID
can
be
specified).
Example:
Diagnosis
of
the
crossbar
cables
and
crossbar
units
between
BBID
0
and
BB-ID
1
Appendix
A
 
Troubleshooting 315

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals