PRIMERGY TX150 S4 User’s Guide
9
Operation and Maintenance
Manually-operated Retention Latch is not
closed at Hot-Plug PCI slot x
The card guide is not closed. Check whether the card guide is
closed. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
No usable CPU Installed CPU error. Replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide". After the
replacement, enable the CPU in the BIOS Setup Utility.
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
Check that the correct CPU is installed. If the correct CPU is
installed and the message is displayed, select [Yes] for the
[Reset Configuration Data] setting on the [Advanced] menu of
the BIOS Setup Utility. If the message still appears, the CPU or
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
CPU disable! CPU is no longer available for
the operateing system.
CPU error. No CPUs available to the system are detected.
Check the error log and replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide". After the
replacement, enable the use of the CPU in the BIOS Setup
Utility.
Invalid System Configuration Data The system configuration is invalid. Select [Yes] for the [Reset
Configuration Data] setting on the [Advanced] menu of the
BIOS Setup Utility.
Resouce Conflict IRQ, DMA, or I/O address conflicts between an onboard
device and an expansion card. Check and modify the
configuration using the BIOS Setup Utility. If the message still
appears, the expansion card or baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
IRQ not configured The IRQ for an onboard device or an expansion card is not
configured. Check and modify the configuration using the
BIOS Setup Utility. If the message still appears, the expansion
card or baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
Expansion ROM not initialized Initialization error of the PCI extended ROM. Disconnect the
initialized device/card on the screen and replace the card. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
Allocation error static node # An onboard device or an expansion card cannot be used.
Disconnect the device/card and replace the card. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
Baseboard Management Controller has
detected an Error
BMC error. The error log needs to be checked and the relevant
part(s) replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
A temperature has exceeded the warning
threshold
The baseboard is at an abnormal temperature. Check the
operating environment. If the message still appears, the error
log needs to be checked and the relevant part(s) replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
A temperature has exceeded the critical
threshold
table: List of POST Errors
Message Description