Overview
2-4
Table 2.3 Initialize Setup Guide
Menu Item Setting Remarks Page
Delete All Msg Deletion of received message
2-25
7-15
All Clear
All settings are reset to default settings and
received messages are deleted.
2-25
7-15
Off
Demo Mode
On
ON/OFF of Demo Mode setting 2-25
System Test
Results
Display of factory self test results
2-25
7-12
View Nav Data Display of input Nav data
2-25
7-12
Off
ZCZC Check
On
Handling of “ZCZC” setting 2-26
B1>00>B2
00 Msg Priority
00>B1>B2
Handling of “00” message setting 2-26
Old -> New
Print Order
New -> Old
Printing order of messages setting in the
received message list (printing order starting
from oldest message/ order starting from
newest message)
2-26
Available Rcv
Station List
Display currently receivable station and
message type
2-27
Adjust Rx Unit NX-7001 adjust mode
2-27
7-13
Initialize 1
Rx Test Receiving self test
2-29
7-13
Ignore
Sumless
NMEA
Receive
Handling of NMEA sentence with or
without checksum
2-27
Ignore
ACK
Command
Receive
Setting whether to enable or disable the
$ACK sentence from the INS
2-28
Serviceman
Test
Self test for serviceman
2-28
7-5
Fill Memory
Setting for type approval to fill the message
storage area to the 100 % use status.
2-28
7-14
Rcv
Mon+NMEA
Test
Display a message being received in real-time
Loop Back test of NMEA data
2-28
7-14
Soft
DX RX
Decision
Hard
Setting for character recognition 2-29
Off
CRLF Check
On
Setting whether to enable or disable <CR>
and <LF> check
2-29
Off
Initialize 2
Russia Mode
Ver-02.01
On
Selection of Russia or IEC standard 2-30