2.3 Setting of System menu
2-17
Table 2.3.1 Alarm Operation
Received
Msg.
Program
Version
ALM beep
output
How to stop alarm
01.02 Stopped by pressing any key
A or B or L
02.01
Every second
ON/OFF
1. Stopped by pressing any key
2. Stopped by the sentence from the INS
Note:
Even when the alarm is outputted by multiple
alarm messages, the alarm is stopped by just
pressing one key as described above.
01.02
Every second
ON/OFF
Same as above
D
02.01
Every 0.5 s
ON/OFF
Same as above
01.02
Every second
ON/OFF
1. Stopped by pressing any key
2. Stopped by the sentence from the INS
Note:
Even when the alarm is outputted by multiple
alarm messages, the alarm is stopped by one
operation (1 or 2) described above.
A or B or
L+ D
02.01
Every 0.125 s
ON/OFF
1. When any key is pressed, the alarm of the
message D is stopped. And then when any key is
pressed, the alarm of the message A, B, and L is
stopped.
2. By the sentence from the INS, alarms of
message A, B, L and D are separately stopped.
2. Signal Monitor (On/Off)
This is the setting whether or not to output a receiving monitor beep on the international
or local frequency. See page 7-10 for details.
3. Key Beep (On/Off)
This is the setting whether or not to output a beep when a key is pressed.
Buzzer
For Receiving monitor beep,
Key click beep