2.7 Setting of Initialize-2 menu
2-28
2.7 Setting of Initialize-2 menu
Differences in the Initialize 2 menu between the programs Ver-01.02 and Ver-02.01 are
the presence of the setting “Russia Mode”.
- Ver-01.02 ! Russia Mode is present.
- Ver-02.01 ! Russia Mode is not present.
1. Sumless NMEA (Ignore/Receive)
This is the setting for handling of sentences without checksum such as the position data.
Basically, the sentence is “without checksum” in case of NMEA Ver-1.5, and “with
checksum” in case of Ver-2.0 and IEC61162.
- Ignore : Does not accept Sentences without checksum.
- Receive : Accept Sentences without checksum.
2. ACK Command (Ignore/Receive)
This is the setting for handling of the ACK sentence that stops an alarm from the INS
when an alarm message is received. Always set this to “Receive”.
- Ignore : Does not accept the ACK sentence.
- Receive : Accept the ACK sentence.
Related setting:
Program Ver-02.01
- Select “On” in [MENU] -> System -> Warn Msg Alm.
(ON/OFF for messages A, B and L. Always “ON” in case of message D)
- Select “INS” in [MENU] -> NAVTEX-> Mask Mode.
Program Ver-01.02
- Select “On” in [MENU] -> System -> Warn Msg Alm.
(ON/OFF for messages A, B and L. Always “ON” in case of message D)
- Select “INS” in [MENU] -> NAVTEX-> Receiver Mode.
3. Serviceman Test
See page 7-5 for details.
4. Fill Memory
See page 7-14 for details.
5. Rcv Mon+NMEA Test
See page 7-14 for details.