102
<Functions of Linkage Menu>
Select the function name
and return to the Linkage
menu by touching the
RTN button.
 
Or the
HOME/EXIT button is
pushed.
<SensorTouch™>
RETURN
SENSOR
Various telemetry sensors setting
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
to the S.BUS2 port of the transmitter.
When using 2 or more of the same kind of
sensor, they must be registered here.
Select [SENSOR] in the Linkage menu and access
the setup screen shown below by touching the
RTN button.
Sensor ID: When multiple sensors of the
same type are not used, ID is unnecessary.
As shown in the table below, an altimeter requires 3 contiguous slots
and a GPS sensor requires 8 contiguous slots. In addition, since the GPS
(SBS-01G) start slots are 8, 16, and 24, slots 6 and 7 are inhibited.
Assignable slot
*Altimeter, GPS, and other sensors that display a large amount of data require multiple slots.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
[What is a slot?]
Servos are classified by CH, but sensors are
classified in units called “slot”. There are slots
from No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
Using a sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a start slot.
When 2 or more of the same kind of sensor are
used, the sensors themselves must allocate unused
slots and memorize that slot.
*3 slots of altitude sensor are used.
*8 slots of GPS sensor are used.
Sensor
Therequired
numberofslots
Thenumberwhichcanbeusedasastartslot Sellingarea
TEMP(SBS-01T) 1slot 1 31
Global
RPM(SBS01RM,SBS-
01RO)
1slot 1 31
Voltage(SBS-01V) 2slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
Altitude(SBS-01A) 3slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,24,2
5,26,27,28,29
GPS(SBS-01G) 8slots 8,16,24
TEMP125-F1713 1slot 1 31
Europe
VARIO-F1712 2slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
VARIO-F1672 2slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,20,21,
22,24,25,26,27,28,29,30
GPS-F1675 8slots 8,16,24