TELEMETRY : BATTERY
Displaying data from the battery voltage
In this screen, the battery voltage is displayed.
In order to use this function, it is necessary to
connect External voltage connector of R7008SB
⇔
SBS-01V
⇔
Battery
SBS-01V measures two batteries. The drive
battery connected to two lines is displayed on EXT-
VOLT. The battery for receivers connected to 3P
lines is displayed here.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in
FASSTest12CH mode.
*The FASSTest14CH mode can use all the telemetry functions.
● Select [BATTERY] in the TELEMETRY screen and
access the setup screen shown below by touching
the RTN button.
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To next page
● battery voltage
● The maximum and the minimum when
powering ON are shown.
● ↓The arrow will indicate that
an alarm will sound when
the voltage drops to below
the setting.
Alert set
1. Move the cursor to the ↓ALERT [INH] item and
touch the RTN button to switch to the data
input mode.
2. Select the ACT mode by scrolling the touch
sensor.
3. Touch the RTN button. (To terminate the input
and return to the original state, touch the S1
button.)
4. Move the cursor to the ↓THRESHOLD [4.0V]
item and touch the RTN button to switch to
the data input mode.
5. Ajust the rate by scrolling the touch sensor.
Initial value: 4.0V
Adjustment range: 0.0V~8.4V
*When the RTN button is touched for one second, the rate is
reset to the initial value.
6. Touch the RTN button. (To terminate the input
and return to the original state, touch the S1
button.)
TYPE1
TYPE2
TYPE3
TYPE4
"Vibes" type
If the following types are selected, the transmitter will
vibrate during the warning.