TELEMETRY : Rx-BATT.
Displaying data from the receiver battery voltage
In this screen, the battery voltage of a receiver is
displayed.
If it becomes higher or lower than the setting an
alarm and/or vibration will alert you.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in
FASSTest12CH mode.
*The FASSTest14CH mode can use all the telemetry functions.
● Select [Rx-BATT.] in the TELEMETRY screen and
access the setup screen shown below by touching
the RTN button.
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To next page
● Receiver battery voltage
● The maximum and the minimum when
powering ON are shown.
● ↓The "down" arrow will
indicate that an alarm will
sound when the voltage
drops to below the setting.
Alert set
1. Move the cursor to the ↓ALERT [INH] item and
touch the RTN button to switch to the data
input mode.
2. Select the ACT mode by scrolling the touch
sensor.
3. Touch the RTN button. (To terminate the input
and return to the original state, touch the S1
button.)
4. Move the cursor to the ↓THRESHOLD [4.0V]
item and touch the RTN button to switch to
the data input mode.
5. Ajust the rate by scrolling the touch sensor.
Initial value: 4.0V
Adjustment range: 0.0V~8.4V
*When the RTN button is touched for one second, the rate is
reset to the initial value.
6. Touch the RTN button. (To terminate the input
and return to the original state, touch the S1
button.)
TYPE1
TYPE2
TYPE3
TYPE4
"Vibes" type
If the following types are selected, the transmitter will
vibrate during the warning.