8G093X01 R5
VR Programming Guide
August 2022 Page 110 of 144
Pass Deny
Response To PSU
Enable / Disable
Check box
If a Local PSU (affiliated through the
VR) PTTs and the System sends back a
Deny response, the VR does one of the
following:
* if the Pass Deny Response Box is
checked → the VR sends a Deny
message to the PSU and the call is
cancelled.
* if the Pass Deny Response Box is
unchecked → the VR enables the PSU
call to be repeated locally (to the other
Local PSUs) but not to the System.
Private Call Setup
Timeout
Determines the time a Local PSU waits
after initiating a Private Call to another
Local PSU to receive a reply from the
destination Local PSU. If the timer
expires before the destination PSU
replies, the VR cancels the Private Call.
Must be set to match the settings of the
PSU.
Affects Private Calls
between Local PSUs
only.
The VR handling of
Private Calls
between Local and
System PSUs is
based on the
Timeout settings of
the P25 System.
Private Call Hang
Timeout
If no PSU activity is detected for the
duration of this timer, the VR cancels
the Private Call and is ready for
servicing other calls.
Telephone
Interconnect CCT
If a telephone call between a local PSU
and the Trunking system is processed
by a given VR and the call exceeds the
programmed timer, the call will be
automatically disconnected. This timer
applies to phone calls only.
Telephone Interc.
Hangtime
If no call activity is detected for the
duration of this timer, the VR cancels
the phone call.
P25 Frame Sync
Detection Timer
Upon Carrier Activated Squelch (CAS)
activation, if the VR digital decoder
does not detect P25 Frame sync before
this timer expires, the VR analog
decoders will be switched on (i.e., PL /
DPL, DTMF, MDC1200…).
Applicable to Mixed
Mode VR Channels
only.