8G093X01 R5
VR Programming Guide
August 2022 Page 109 of 144
Tone Setup
The tones setup screen allows programming of custom tones / tone sequences, which are sent by the VR
to the Analog PSUs during Analog Mode of operation only.
If no custom tones are programmed, the VR will send the default sets of tones.
NOTE:
The tones sent by the VR in analog mode are heard by all analog PSUs, which are tuned to the same VR
channel and are within the VR RF coverage area.
Station ID Setup
Morse Code
The Morse code option needs to be programmed only when a VR is to be used as a fixed repeater
and the FCC rules require transmission of Repeater ID via Morse Code.
Digital Setup
Pass Queue
Response To PSU
Enable / Disable
Check box
If a Local PSU (affiliated through the
VR) PTTs and the Call is Queued by
the Trunking System, the VR does one
of the following:
* if the Pass Queue Response Box is
checked → the VR sends a Queue
message to the PSU and forces the
PSU to wait until System grant is
received or
* if the Pass Queue Response Box is
unchecked → the VR enables the PSU
Call to be repeated locally (to the other
Local PSUs while it is not repeated on
the System side).
Local to System
Call Upgrade
Enabled
Enable / Disable
Check box
When a Call from a Local PSU
(affiliated through the VR) has been put
in the Queue by the System or blocked
by MSU conflicting service, and System
grant is received during the VR’s Local
repeat of the PSU Call, one of the
following will occur:
* if the Local to System Call Upgrade
Enabled is checked → the VR
promotes the Local Call to System so
that the remainder of the PSU Call is
repeated to the System Users or
* if the Local to System Call Upgrade
Enabled is unchecked → the VR
repeats the Call Locally only until the
Call is completed.
This setting is
applicable if the
Pass Queue
Response to PSU
is Disabled i.e.,
Unchecked or the
System Channel
Acquisition time
(see System Setup
2) has been
exceeded.