Troubleshooting
Software / Programming Related Problems
Most of the VR Programming problems are caused by mismatched MSU, VR and portable radio
templates. Note that any updates to the MSU or the PSU templates may require corresponding
changes to be made in the VR template.
All RM-OTAP related warning / error messages are displayed for 30 seconds for up to 5 power
cycles. To prevent these messages from displaying, power cycle the repeater 5 times. All these
messages are identified with an asterisk (*).
The following error & warning codes may be displayed on the MSU control head:
Control Head Display
Description / Action
Affichage de la tête de
commande
CFG UPDT FAIL1*
An error was encountered with the DCD template file. Create a new
DCD file and reapply.
ERR MAJ CNFG1*
CFG UPDT FAIL2*
Hardware part number mismatch. Ensure that the DCD file
frequency information aligns with frequency band of the repeater.
Also ensure that the DCD repeater model aligns with the repeater.
The repeater part number information is found here:
Hardware/Software Info Hardware Part Number: 7V087xxx (for
VRX1000), 7V083xxx/7V093xxx (for DVR/DVR-LX). Then reapply
the DCD file.
ERR MAJ CNFG2*
CFG UPDT FAIL3*
Hardware model and revision mismatch. Ensure that the DCD file
repeater model aligns with the repeater. The repeater model
information is found here: Hardware/Software Info Hardware
Model and Revision: 001.01 (for duplex) 002.01 (for simplex). Then
reapply the DCD file.
ERR MAJ CNFG3*
CFG UPDT FAIL4
An error was encountered with the DCD template file. Create a new
DCD file and reapply.
ERR MAJ CNFG4
CFG UPDT FAIL5
The DCD file has errors. Use FRC to edit and resolve all DCD
configuration errors and then reapply.
ERR MAJ CNFG5
CFG UPDT FAIL6
Serial Number mismatch. Verify repeater serial number is valid for
the DCD file and then reapply. See:
How To Create a DCD File
ERR MAJ CNFG6
CFG UPDT FAIL7
DCD file is an unsupported revision type. Open and save DCD file
with latest FRC and then reapply.
ERR MAJ CNFG7
CFG UPDT FAIL8
DCD file application failed. RM-OTAP license must be installed on
repeater. Bundle license file with DCD and reapply.
ERR MAJ CNFG8
DUPL: [PSUid]
If Duplicate PSU ID is detected, VR displays the warning message
on Control Head’s DVR line.
FAILURE TO READ
REPEATER
1. Ensure only one instance of FRC is open
2. Make a second attempt to read VR