EasyManua.ls Logo

Futurecom VR - Page 131

Default Icon
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8G093X01 R5
VR Programming Guide
August 2022 Page 131 of 144
Control Head Display
Description / Action
Affichage de la tête de
commande
ÉCHEC DE LECTURE DU
RÉPÉTEUR
3. Re-connect USB (disconnect / connect, wait few seconds
for device to be recognized, try to read VR again)
4. power-cycle VR by turning MSU off and on again, wait few
seconds until VR is on and USB connects, then try to read
VR. If device not recognized or read fails again, try power-
cycling VR one more time
5. If still unable to read, reboot PC
FW UPDT FAIL1
An error was encountered with the firmware. Try applying again
using RM. If error persists, download a new copy of the firmware
bundle from MSI and reapply using RM.
ERR MAJ FW1
FW UPDT FAIL2
An error was encountered with the firmware. Try applying again
using RM. If error persists, download a new copy of the firmware
bundle from MSI and reapply using RM.
ERR MAJ FW2
FW UPDT FAIL3
Firmware encryption error. Contact Futurecom.
ERR MAJ FW3
FW UPDT FAIL4
Firmware packaging error. Contact Futurecom.
ERR MAJ FW4
ID MISCONFIG
Indicates a PSU ID misconfiguration has been detected. Requires
PSU ID change. Occurs when Forced Analog is being used on an
analog mobile channel and the P25 ID does not translate to a valid
MDC ID. Either pick a valid ID or turn off PTT ID on analog channels
in Mobile Radio Channel Setup.
INCOMP MSU HW
Indicates incompatible MSU hardware (XTL MSU connected to an
APX compatible VR). Ensure to connect a compatible APX MSU or
change the VR to an XTL compatible model.
LIC UPDT FAIL
RM-OTAP license installation failed. Confirm serial number of
repeater. Contact FC for a new license file for this repeater. Verify
repeater serial number is valid for the DCD file. Bundle the new
license file with DCD file and reapply. See
How To Create a DCD File
ERR MAJ LIC
LOW BATTERY
Indicates Low Battery Warning or Alarm.
BATT BAS
MISMATCH ERROR or
VR FW MISMATCH
Repeater and Motorola Mobile Radio Firmware are not compatible.
Please check Futurecom website for Compatibility Chart.
NOT ALLOWED
Displayed when VR is in Off mode and user attempts to set as
Permanent Primary. VR must be in System or Local Mode.
OR
Displayed after long pressing the DVRS button when user attempts
to set VR as Permanent Primary and control not configured. Use
FRC to configure Primary/Secondary Setup Permanent Primary
Control Enabled field.
See Primary / Secondary Setup
INTERDIT
RC ERROR 1000
Displayed permanently indicates that both the Main and Backup
EEPROM maps are corrupted, and the unit is not operational.
Please contact Futurecom for further instructions on how to
troubleshoot the problem.
RC ERREUR 1000
RC ERROR 4000
Indicates that the VR firmware has been updated but its
programmed personality has not. The VR personality needs to be
updated by reading the unit with the Futurecom Repeater

Table of Contents