8G093X01 R5
VR Programming Guide
August 2022 Page 123 of 144
BER Test Setup
The following is required to be able to measure BER on the Futurecom Repeater Configurator
Monitoring Screen:
1. Connect a Radio Communication Testset or equivalent to the VR Antenna port and set it
up as described below:
Program TX frequency matching the programmed VR Rx Frequency
PATTERN 1011
MODULATION P25
NAC 293
ALGID 80
MFID 00
TGID 1
SID 000001
2. Set the Test Mode AND P25 Rx Modem Test Test Mode to ‘YES
3. Lower the Radio Communication Testset transmit level until desired BER Threshold is
observed on the Monitoring screen.