8G093X01 R5
VR Programming Guide
August 2022 Page 98 of 144
VR Common Setup
Field Name
Range
Description
Notes
Local Mode
Allowed
Check box
(checked)
Enables / Disables
Local VR Mode
selection by the
User through the
control head or
remote activation
methods.
To prevent fallback to local repeat when system not
available, refer to "Block Fallback to Local Repeat"
Rptr
Independent
Channel
Change
Check box
(checked)
When Enabled
(checked) the VR
channel can be
selected
independently from
the selected MSU
channel. When
Disabled
(unchecked), the
VR channel is
strapped to the
selected MSU
channel.
Refer to Table 4 - Field Interactions Determining
VR Mode on Power Up
Power UP
Options
Mode
Fixed
Last
Programmed
Specifies the VR
Mode upon Power
Up. When
‘Programmed’ is
selected, the VR
Mode is as
programmed for the
selected VR
channel or MSU
Mode.
If AVRA is Enabled, then Power Up mode is driven
by the AVRA input.
Fixed Mode
System
Local
OFF
Specifies the VR
Mode when Fixed
Power up option is
selected.
Typical
recommended
setting is OFF.
Default setting for vehicular mount models is OFF
Channel
0 to max.
value
programmed
in Repeater
Channel
Setup.
0 displayed
as ‘Disable’
Specifies the
Default VR Power
up Channel.
If set to Disable the VR reverts to the last used
channel upon power up.

Table of Contents