8G093X01 R5
VR Programming Guide
August 2022 Page 92 of 144
Enable / Disable
Check box
This field needs to be enabled on
VR models using an external light
which is lit when a VR is a Primary
or Permanent Primary.
This option requires
external switching logic
and hardware (provided
by installer).
Relay Use > Relay 2
must be set to ‘Master
Light’ due to the Auxiliary
Cable wiring.
‘Not Used’
‘MSU RF
Bypass Sw.’
‘Master Light’
‘LOC Mode
Light’
‘SYS Mode
Light’
‘VR ON light’
‘External Alarm’
‘Duplexer
Bypass Sw.’
This field identifies the option that
is controlled by the Relay 1 output
of the VR auxiliary cable.
Relay 1 must be assigned to the
MSU RF Bypass Switch if the
option is installed.
The MSU RF Bypass
Switch option is included
with all in-band VRs
All Lights and associated
external logic are to be
provided by installer.
External Alarm for
Rackmount DVR
Duplexer Bypass Switch
option not currently
available.
Refer to DVR-LX
Installation Guide for
further information.
This field identifies the option that
is controlled by the Relay 2 output
of the VR auxiliary cable.
This field identifies the option that
is controlled by the Relay 3 output
of the VR auxiliary cable.
Min/OFF (0)
Default (70)
Max (100)
Range 50-100
Alarm will sound when
temperature sensor in repeater
exceeds programmed temperature
threshold (measured in degrees
Celsius).
Only accessible if
Hardware Setup→Relay
Use→Relay #→External
Alarm is selected
Min/Default
(OFF) (0)
Max 5dB
Alarm will sound when output
power of repeater is exceeded by
the value programmed.
Only accessible if
Hardware Setup→Relay
Use→Relay #→External
Alarm is selected
Enables or Disables the
Cumulative Automated Frequency
Control (AFC) tuning.
Default setting is Enable.
Set to Disable during
calibration.
Enables or Disables the Fast AFC
tuning.
Default setting is Enable.
Set to Disable during
calibration.
Enable / Disable
Check box
If a VR is to be used as a tactical
repeater (without any mobile radio
interfaced to it) this field must be
set to Enable.
A Tactical VR model
requires a different Power
cable that allows the VR
to be powered up by itself
i.e., does not require a
powered up MSU
connected to it.
MSU Data
This screen provides MSU data for information purposes only.