8G093X01 R5
VR Programming Guide
August 2022 Page 94 of 144
Analog Setup
Enables (checked) or Disables
(unchecked) the Trailing Tones
sent by the VR to the Local PSUs
to indicate state of the
transmission.
The tones are sent at the end of
LPSU transmission.
Affects Analog VR Mode
when used with Trunked
MSU mode only. The
tones are heard by all
LPSU users that are on the
selected VR channel since
they are sent over the air
(not generated in the
LPSU).
Enables (checked) or Disables
(unchecked) the Lead Go Ahead
Tones sent by the VR to the Local
PSUs to indicate successful /
unsuccessful system channel
access. The tones are sent at the
beginning of LPSU transmission.
The LPSU user needs to do
‘double PTT’ to be able to hear the
Lead tones.
Affects Analog VR Mode
when used with Trunked
MSU mode only. The
tones are heard by all
LPSU users that are on the
selected VR channel since
they are sent over the air
(not generated in the
LPSU).
Enables (checked) or Disables
(unchecked) the Trailing Tones
sent by the VR to the Local PSUs
to indicate successful /
unsuccessful VR transmission.
The tones are sent at the end of
LPSU transmission.
The tones are heard by all
LPSU users that are on the
selected VR channel since
they are sent over the air
(not generated in the
LPSU).
Enables (checked) or Disables
(unchecked) the Lead Go Ahead
Tones sent by the VR to the Local
PSUs to indicate successful /
unsuccessful VR transmission.
The tones are sent at the
beginning of LPSU transmission.
The LPSU user needs to do
‘double PTT’ to be able to hear the
Lead tones.
Affects Analog VR Mode
when used with Trunked
MSU mode only. The
tones are heard by all
LPSU users that are on the
selected VR channel since
they are sent over the air
(not generated in the
LPSU).
Portable
Trunk
Simulated
Access
Enabled (checked) only when the
PSU user is expected to do
‘Double PTT’ and Leading Tones
are enabled.
Upon receiving a matching DTMF
sequence from a PSU, the VR
switches from OFF or Local to
System Mode. The VR and PSU
must be programmed with the
same DTMF sequence.
The PSU must be
programmed with * as the
last DTMF sign, for
example 1234*.