EasyManua.ls Logo

Futurecom VR - How to Program Unit ID Translation

Default Icon
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8G093X01 R5
VR Programming Guide
August 2022 Page 62 of 144
How to Program Unit ID Translation
FRC- VR Programming
Step 1: Open the Digital Setup window.
Step 2: Confirm that the Enforce TG Matching field is unchecked.
Step 3: Open the Repeater Channel Setup window.
Step 4: Scroll to the far right and set the UID TRNSL. Field to Yes for each required channel.
Additional Notes
1. Programming- only applicable to digital channels.
2. Programming- overrides Talkgroup Proxying and Translation features.
3. Programming- incompatible with PSU Authentication feature.