60 ADV200 SP • Quick start up guide - Specification and installation
• Example: Changing the Speed Reference source
Ramp ref 1 mon
Ramp setpoint Block”.
Its default source is the Analog input 1 mon Analog
input 1 Block”, which in this case refers to analog input 1 of the signal terminal strip.
To change the reference source from the analog input to a digital reference inside the drive, the input signal
Ramp setpoint Block”.
Ramp ref 1 src parameter (PAR: 610) and set a new reference, selecting it from among those listed
Dig ramp ref 1 (PAR: 600).
• Example: Inverting the analog reference signal
To invert the “Analog input 1 Block” output signal, the value of the An inp 1 sign src parameter (PAR: 1526),
which has a default setting of
Digital input X mon, One (func-
+1
-1
*-1
*+1
Analog input1mon
Analog input1Block
Ramp Setpoint Block
Null
Null
Terminal input
Ramp ref1mon
Ramp ref 1 src
An inp 1 sign src
Null
An inp1alt value
An inp1alt sel src
Ramp ref invert src
Note ! This section contains a brief description of the functions of the other parameters in the function blocks not included
for the changes in the example.
The An inp 1 alt sel srcAnalog
input 1 mon (PAR: 1500) output.
The An inp 1 alt value parameter (PAR: 1524) determines the alternative reference value for the Analog
input 1 mon (PAR: 1500) output.
The Ramp ref invert src
the “Ramp setpoint
The output signal from the “Ramp setpointRamp ref 1 mon parameter (PAR: 620).