Rev. 00 03/19
OptiStar 4.0 (CG24-CP) Start-up
33
No.
Description
Values
Display
P04
Interface type
0: Deactivated
1: Automatic
recognition
OFF
Auto
P05
CAN Baud
rate
0: 20 kbit/s
1: 50 kbit/s
2: 100 kbit/s
3: 125 kbit/s
4: 250 kbit/s
5: 500 kbit/s
6: 800 kbit/s
7: 1 Mbit/s
2 0
5 0
1 0 0
1 2 5
2 5 0
5 0 0
8 0 0
1 0 0 0
P06
CAN Node ID
1-127
P08
Procedure
when
changing
Local /
Remote
0: Gun release is reset
1: Gun release is not
changed
RCHG
P09
Pump
operating
mode
0: Individual operation
1: Parallel operation
SoLo
dUo
P10
Log level
0, 1, 2, 3, 4, 5
LoG
P11
Bluetooth ID
no.
0: Bluetooth
deactivated
1 - 255
blid
P12
Remote
Manual Gun
0: Powder output +/-
PowerClean
(Activation)
PAC
1 : Program change
PowerClean
(Activation)
PrC
2: Powder output +/-
PowerBoost
(Activation)
PAb
1)
is not overwritten, if a Memory Reset is performed
Default values are marked by bold print.
7. Press key to quit the system parameter mode.
The display switches to the standard level