Troubleshooting for SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016 75
State Description PWR STAT 1 STAT 2 FAULT
Ethernet Fault Could not configure
an internal Ethernet
switch.
On Off Off Blinks on
every three
seconds
Firmware Fault A critical fault
was detected in
the control board
microcontroller.
On Off Off On
SBC 1 On-line First SBC is
operational.
On Blinks off
every three
seconds
N/A Off
SBC 1 Off-line First SBC is not
operational.
On Blinks on
every three
seconds
N/A Off
SBC 2 On-line Second SBC is
operational.
On N/A Blinks off
every three
seconds
Off
SBC 2 Off-line Second SBC is not
operational.
On N/A Blinks on
every three
seconds
Off
Ignition Cut The ignition was
cut. Unit is in a
preshutdown grace
period (default
10 seconds). If
ignition is restored
within this period,
the shutdown is
cancelled.
Blinks off
every three
seconds
Off Off Off
Platereader/
SBC shutdown
The unit will
shutdown shortly
(default 20 seconds)
in response to an
external event.
Toggles
once per
second
Off Off Off
Firmware
update request
The LPR Processing
Unit firmware
update is beginning
shortly. The unit
will restart after
completion (5
minutes max).
On On Off Blinks three
times then
off