What to do if my Ginlong Inverter displays PV ISO-PRO 01/02 error?
J
John IngramSep 7, 2025
If your Ginlong Inverter displays PV ISO-PRO 01/02, remove all DC input, reconnect and restart the inverter one by one. Identify which string causes the fault and check the isolation of that string.
C
Carrie HuynhSep 8, 2025
What does DC-INTF OV-DCA-I error mean on Ginlong Solis 5G Inverter?
C
carrierobbinsSep 8, 2025
If your Ginlong Inverter displays DC-INTF OV-DCA-I, restart the inverter. Identify and remove the string to the fault MPPT. If the issue persists, consider changing the power board.
M
Maria MartinezSep 10, 2025
How to fix OV-BUS error on Ginlong Solis 5G Inverter?
S
Sara CainSep 10, 2025
If your Ginlong Inverter displays OV-BUS, check the inverter inductor connection and the driver connection.