EasyManua.ls Logo

Graco LineLazer V250SPS - User Manual

Graco LineLazer V250SPS
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For the application of line striping materials.
For professional use only.
For outdoor use only.
Not for use in explosive atmospheres or hazardous locations.
Maximum Operating Speed: 10 mph (16 kph)
Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in this manual and in related manuals.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
Model Guns
Pressurized
Bead System
Description
17H471 2 No LLV 250DC
17H472 3 No LLV 250DC
17H473 2 Yes - 2 Tank LLV 250DC
17H474 3 Yes - 2 Tank LLV 250DC
17H466 1 No LLV 250SPS
17H467 2 No LLV 250SPS
17H468 1 Yes - 1 Tank LLV 250SPS
17J951 2 Yes - 1 Tank LLV 250SPS
17H469 2 Yes - 2 Tank LLV 250SPS
Related Manuals:
3A3394 Repair / Parts
311254 Gun
309277 Pump
3A3428 Auto-Layout Applications Methods
332230 Pressurized Bead System (PBS)
Operation
LineLazer V 250SPS and 250DC
Self-Propelled Line Striper
3A3393C
EN
Use only genuine Graco replacement parts.
The use of non-Graco replacement parts may void warranty.

Other manuals for Graco LineLazer V250SPS

Questions and Answers

  • L
    lisagomezSep 8, 2025
    Why does my Graco LineLazer V250SPS sprayer overheat?
    • J
      Joshua FoxSep 8, 2025
      Your sprayer may be overheating due to paint buildup on the hydraulic components, which requires cleaning. Another potential cause is a low hydraulic oil level; if so, fill it with hydraulic oil.
  • S
    Sergio FriedmanSep 7, 2025
    What causes excessive paint leakage into the throat packing nut of my Graco Construction Equipment?
    • M
      Mark BarrettSep 7, 2025
      Excessive paint leakage into the throat packing nut can occur if the throat packing nut is loose. Remove the throat packing nut spacer and tighten the nut just enough to stop the leakage. Another cause could be worn or damaged throat packings. In some cases, the displacement rod may be worn or damaged.
  • J
    Justin HerreraAug 22, 2025
    Why won't my Graco Construction Equipment engine start?
    • D
      Debra BlankenshipAug 22, 2025
      Several factors can prevent your Graco Construction Equipment engine from starting. First, ensure the engine has gas and the fuel shut-off lever is in the ON position. Check the engine oil level and add oil if needed. If the engine is cold, use the choke. Inspect the spark plug cable for disconnections or damage, and connect or replace it if necessary. A defective key switch or a disconnected/defective main wire harness could also be the cause; replace or reconnect them accordingly.
  • D
    Dawn GarciaSep 4, 2025
    What causes low output on the upstroke of the displacement pump in my Graco Construction Equipment?
    • B
      brandon95Sep 4, 2025
      If the displacement pump operates but the output is low on the upstroke, it could be that the piston ball is not seating properly. Another possibility is that the piston packings are worn or damaged.
  • E
    Edward RodriguezSep 3, 2025
    Why is the stall or run pressure low on my Graco Construction Equipment display?
    • G
      Gary RogersSep 3, 2025
      A low stall or run pressure on the display might be due to a pressure setting that is too low; turn the pressure adjusting knob clockwise to increase the pressure. If you have a new pump or new packings, keep in mind that the pump break-in period can take up to 100 gallons of material. A faulty transducer could also be the cause, requiring replacement.
  • A
    Ashley CarterSep 2, 2025
    What to check if Graco LineLazer V250SPS gun does not trigger?
    • K
      Kristin JonesSep 2, 2025
      If the gun on your Graco Construction Equipment isn't triggering, first ensure the engine clutch switch and the gun selector switch are both turned ON. If the display is in AUTO MODE, make sure the ground speed is greater than 0.7 mph (1.1 kph). Verify that the system pressure is at least 1000 psi. Also, check the gun cable and wires from the control board to the solenoid for disconnections or breaks, reconnecting or replacing them as needed.
  • D
    David GregoryAug 31, 2025
    Why is the pump on my Graco LineLazer V250SPS Construction Equipment difficult to prime?
    • P
      pjonesAug 31, 2025
      A pump that's difficult to prime may have a clogged suction tube strainer, which needs cleaning. A suction tube air leak requires tightening. Also, check for a clogged drain line to the paint hopper and clean it if necessary. An intake valve leak could be the problem; clean the intake valve, ensuring the ball seat is in good condition. Worn pump packings can also cause priming issues. If the paint is too thick, thin it according to the supplier's recommendations. Finally, ensure the engine speed isn't too high during priming.
  • M
    Mitchell MurphyAug 30, 2025
    What causes low output on the downstroke of the displacement pump in my Graco LineLazer V250SPS Construction Equipment?
    • J
      Justin BenderAug 30, 2025
      Low output on the downstroke (or both sides) of the displacement pump can be caused by several issues. A clogged suction tube strainer needs cleaning, or a suction tube air leak requires tightening. Ensure the pressure setting is adequate. Clean a clogged or dirty fluid filter or tip. Verify that the engine speed is sufficient. Other causes include an intake valve ball packed with material, worn or damaged pump packings, a large pressure drop in the hose, a dirty or clogged oil reservoir hydraulic filter, or a loose intake line to the pump inlet. In some cases, the hydraulic motor may be worn or damaged.
  • Y
    ygarrettAug 28, 2025
    What should I check if the engine runs but the displacement pump doesn't on my Graco Construction Equipment?
    • A
      Amy LongAug 28, 2025
      If the engine is running but the displacement pump isn't operating, make sure the engine clutch switch and the pump ball valve are both turned ON. Check if the pressure setting is too low. Ensure the prime/drain valve is open if the system is pressurized. Also, verify that the hydraulic fluid level is sufficient. If these steps don't resolve the issue, other potential causes include a worn, broken, or off-the-pulley oil reservoir belt, a clogged tip, a stuck displacement pump piston rod, or a hydraulic motor that isn't shifting.
  • E
    Elizabeth LucasAug 27, 2025
    Why does my Graco LineLazer V250SPS engine crank slowly?
    • C
      Christopher ZimmermanAug 28, 2025
      If your Graco Construction Equipment engine cranks slowly, it might be due to excessive hydraulic load. Ensure the engine clutch switch is turned OFF.

Graco LineLazer V250SPS Specifications

General IconGeneral
SmartControlYes
Gun Capacity1
Power SourceGasoline
MaterialSteel
Max Operating Pressure3300 psi
Operating Pressure3300 psi
Max Tip Size0.031 inches
Hose Length50 ft (15 m)
Hose Diameter1/4 inch