Version 2.4 Page 37
FRC.OUT (Force Outputs)
Forces each of the output drivers in turn on. All outputs turn OFF when leaving this step. The
<EDT> key will advance through each output (e.g. ON.1 and ON.2). Pressing <OK> will turn all
outputs off and exit the test.
FACTORY
This is the factory adjustment menu.
DEFLT (Factory Default)
This parameter restores all setup parameters with the exception of the calibration (CAL) and build
(BUILD) menus back to the original factory settings. The main use of this routine is to completely
reset an indicator which is being installed on a different scale.
The Model 250 will prompt with “Cont. N”. The default the indicator, press <EDT> to select “Cont.
Y” and <OK> to continue. “DONE” will be displayed after the default is complete.
END
The parameter can be used for exiting the setup mode. Refer to page 28 for details.
S
S
P
P
E
E
C
C
I
I
A
A
L
L
F
F
U
U
N
N
C
C
T
T
I
I
O
O
N
N
S
S
The Model 250 has a special function key on the front panel. The function of this key can
be configured to any of the key functions detailed below. Refer to KEY.FN (Key
Functions) on page 33 for configuration details.
When leaving the factory, the [ f ] key has no primary function pre-programmed. Each primary
function has an associated overlay sticker (supplied) that should be applied to the function key to
label the function. Ensure the keypad is clean and dry before affixing the sticker. Refer to
Cleaning page 13 for more information.
NONE
When set to NONE the special function key is not used during normal operation. This is the
default setting.
TEST
The [TEST] key is used to test the functionality of the indicator’s display.
Press the [TEST] key to clear the display and show all segments of the display. The display will
be cleared again before returning to the weigh mode.
COUNT
The [COUNT] key is used for counting pieces. Pressing the [COUNT] key will toggle between
the count and weight display. The annunciator for the count mode will be distinguished by a p for
pieces.