Page 56 250 Technical Reference
Register Description Code Example
Counts each new reading 0020 00169196
Indicator status 0021 00000200
Indicator error status 0022 00000000
Absolute signal in mV/V 0023 00006187
Displayed weight reading 0024 000005DC
Gross or Net weight 0025 000005DC
Gross weight 0026 000005DC
Net weight 0027 000001F4
Tare weight 0028 000003E8
Peak held weight 0029 000009C4
Manual held weight 002A 00000000
Total weight reading 002B 000009C4
Livestock weight 002C 0000001F4
Index for first register data 0042 00000001
Index for second register data 0043 00000002
Index for third register data 0044 00000005
Actual full access code 00D0 000004D2
Actual safe access code 00D1 000009C4
Weight used for calibration 0100 000005DC
Calibrated zero mV/V 0111 FFFFFFFF
Calibrated span weight 0112 000009C4
Calibrated span mV/V 0113 000061A8
Weight at linearization points
>00100000 means no point
0114
0118
08000001
Fullscale setting 0121 00000BB8
Resolution setting 0122 00000000
Decimal point position 0128 00000000
Units selection 0129 00000000
4/6 wire operation 012A 00000000
High resolution (x10) mode 012B 00000000
Trade or industrial operation 0130 00000000
Filtering setting 0131 00000000
Motion setting 0132 00000000
Zero range setting 0133 00000000
Zero tracking setting 0134 00000000
Initial zero operation 0135 00000000
Zero band setting 0136 00000000
Type of serial output 0140 00000000
Baud rate 0141 00000000
Parity and stop bits 0142 00000000
Network address 0143 0000001F
Reset printer sequence command 0144
Full date/time string 0150 10/16/2005 10:32
Date format selection 0151 00000000
Date 0152 00000011
Month 0153 0000000A
Year 0154 000007D3
Hour 0155 0000000A
Minute 0156 00000020

Table of Contents