31
Technical Parameters
Back
Alarm record: 02
08 Zone GAS
Back
11/26 15:12
01 Zone SOS
System disarmed
Fig 1: press ESC in disarm Fig 2: press 4 or 6 to check Fig 3: press 4 or 6 to check
Chapter 6. Technical Parameters
List 1
Functions that could be realized by SMS:
Alarm record: 01
Operation figures:
11:49 11/26/2013
11/26 21:12
status
Function
SMS reply by the panel
Arm the system
123456#1#
Disarm the system
123456#2#
Check IMEI number
123456#60#
IMEI number
Check the system status
123456#61#
SMS (take the default
operate password as
examples)
The system status: disarm
Or The system status: arm
Or The system status: home arm
IMEI number
set successful
set successful
Input Voltage
Standby Current
Alarming Current
Wireless Frequency
GSM Frequency
Wireless Receiving Sensitivity
Anti-interference
Back-up Battery
Siren Volume
Wireless Sensors
Remote Controls
Working Temperature
Humidity
AC=110~240V±10%, DC12V/1A
<20mA
<400mA
315/433MHz, PT2262/EV1527, 4.7MΩ
850/ 900/ 1800/ 1900MHz
5mV/m
1V/m (frequency range: 20~1000MHz)
LI AAA*6 DC7.2V
110dB
100pcs
8pcs
0℃~+40℃
≤90% (no fog)