EasyManua.ls Logo

GW Instek GPP-3060 - Page 147

GW Instek GPP-3060
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
147
Function
Sets the output number of Delay.
Description
<NRf> 1 - 2048
Example
:DELAy2:GROUPs 100
Sets the output number of Delay as 100 for CH2.
Command
:DELAy[1|2]:GROUPs?
Function
Queries the output number of Delay.
Example
:DELAy2:GROUPs?
Return the output number of Delay for CH2.
Command
:DELAy[1|2]:PARAmeter <No>,{ON|OFF},<time>
Function
Sets the delay parameter of Delay.
Description
<No> 0-2047 Sets the serial number of delay
parameter. Integer 0-2047.
{ON|OFF} The output state of the group.
<time> 1s-300s The delay duration of the group.
Integer 1s-300s.
Example
:DELAy2:PARAmeter 1,ON,10
Sets the delay parameter of Delay as the 1st group,
output ON, delay 10s for CH2.
Command
:DELAy[1|2]:PARAmeter? <No>[,<count>]

Table of Contents

Related product manuals