Example
:DELAy2:CYCLEs N,100
Sets the cycle number of Delay as 100 for CH2.
Command
:DELAy[1|2]:CYCLEs?
Function
Queries the cycle number of Delay.
Example
:DELAy2:CYCLEs?
Return to I or N, <value> for CH2 (For example:
N,100).
Command
:DELAy[1|2]:ENDState {ON|OFF|LAST}
Function
Sets the termination state of Delay.
Description
ON|OFF|LAST
ON: output enabled.
OFF: output disabled.
LAST: stay at the last group of output state.
Example
:DELAy2:ENDState OFF
Sets the termination state of Delay as output
disabled for CH2.
Command
:DELAy[1|2]:ENDState?
Function
Queries the termination state of Delay.
Description
ON|OFF|LAST
ON: output enabled
OFF: output disabled
LAST: stay at the last group of output state.
Example
:DELAy2:ENDState?
Return the termination state of Delay for CH2.
Command
:DELAy[1|2]:GROUPs <NRf>