REMOTE CONTROL
173
Function
Sets the sequential number of channel sequence
output templet to strat execution.
Example
:SEQUence2:TEMPlet:STARt 100
Sets the initial number of CH2 sequence output
templet as 100.
Command
:SEQUence[1|2]:TEMPlet:STARt?
Function
Queries the sequential number of channel
sequence output to strat execution.
Example
:SEQUence2:TEMPlet:STARt?
Returns to the initial number of CH2 sequence
output templet.
Command
:SEQUence[1|2]:MEMory:SAVE
{0|1|2|3|4|5|6|7|8|9}
Function
Saves the channel sequence output file to the
designated location of internal storage.
{0|1|2|3|4|5|6|7|8|9} represent the storage
locations of 10 files within the internal storage
individually.
Example
:SEQUence2:MEMory:SAVE 1
Saves the CH2 sequence output file to the
SEQUENCE01 location of internal storage.
Command
:SEQUence[1|2]:MEMory:LOAD
{0|1|2|3|4|5|6|7|8|9}
Function
Recalls the channel sequence output file saved in
the designated location from internal storage.
{0|1|2|3|4|5|6|7|8|9} represent the storage
locations of 10 files within the internal storage
individually.